PLD500-EVCSA-36 programmable chargers offer 500W constant current and constant voltage outputs for applications such as electric vehicle and systems with batteries, especially Lithium batteries. Featuring with programmable parameters and charging profile, this series of products provide the system with an optimized charging capability.
Features
Product Specifications
Input Parameters | |||
Input Voltage |
Min. Typ. Max. |
90 115/230 305 |
Vac |
Input Frequency |
Typ. |
47~63 |
Hz |
Power Factor @ Full Load, 115Vac @ Full Load, 230Vac |
Min. Min |
0.99 0.95 |
|
Input Current @ Full Load, 115Vac @ Full Load, 230Vac |
Max. Max |
5.22 2.66 |
A
|
Efficiency @ Full Load, 115Vac @ Full Load, 230Vac |
Typ. Typ. |
93.5 95.5 |
% |
36V Charger Output Parameters | |||
Output Current Setting Range |
Min. Typ. Max. |
5952 11905 13095 |
mA |
Output Voltage Setting Range |
Min. |
25 |
V |
Trickle Charging Current Range |
Min. Typ. Max |
1190 2381 5952 |
mA |
Trickle Charging Voltage Range |
Min. Max |
20 25 |
V
|
The charging current is programmable between 5952mA and 13095mA. The no load output voltage is programmable with maximal output power of 500W.
The output current peak value is less than 14.3A during start up and shut down with full load and 25oC, measured with 20MHz bandwidth
Prtections
Short Circuit Protection |
Auto recovery. |
Over Voltage Protection |
Auto recovery. OVP level programmable at 3~5V above the constant voltage level. |
Over Temperature Protection |
Auto recovery. |
Open Circuit Protection |
Auto recovery |
Derating Curves
Charging Profile
Programmable Profile with "Turbo Charging" TM